Delsys EMG Setup

Overview

Starting from Motive version 3.0 and above, the digital integration of Delsys Trigno Avanti systems is supported. Through this integration, electromyography (EMG) measurements from the Trigno Avanti EMG sensors can be recorded in Motive along with the tracking data. This page provides instructions on how to set up the Delsys Trigno Avanti platform along with the OptiTrack motion capture system.

Required Components

  • Prime series Ethernet camera system

  • eSync synchronization hub

  • Motive 3.0 or above

  • Delsys Trigno Avanti Platform with EMG sensors

  • Delsys Trigger Module for synchronization

  • Trigno EMGworks OR Delsys SDK server package version 3.5.8 or above.

  • Firmware on both the Trigno base station and the sensors must be updated. If the firmware is installed, use the Software Update Tool to install the latest firmware. For more information, please refer to the manufacturer documentation.

Notes

  • Supported Sensors: Integration is supported for Delsys Trigno EMG systems with Trigno Avanti sensors only.

  • Supported Data Channels: Data channels for EMG measurements will be reported in Motive. Data channels for the inertial measurement unit (IMU) and accelerometer are not supported.

  • Supported Device/Channel Count: Integration supports one Trigno base station with up to 16 EMG data channels. Additional devices and/or data channels above this limit cannot be integrated due to a restriction of the Delsys SDK.

  • Synchronization: Synchronization with the motion capture system requires the Delsys Trigger Module and the eSync synchronization hub. Supports triggered sync only.

  • Delsys Trigno Control Utility software must be running prior to launching Motive.

Hardware Setup

Below are two diagrams depicting two types of Delsys hardware setups. One without a NI-DAQ device, and one with a NI-DAQ device. When setting up a configuration without a NI-DAQ device, you'll use a Delsys Trigger Module. This will only allow the option for Trigger Synchronization. If you use a NI-DAQ configuration, however, you have the option to use either Trigger and Reference Clock Synchronization. For more information about synchronization, please scroll down to the Synchronization section of this page.

Software Setup

Device Firmware

Please make sure the firmwares on both the Trigno Base Station and the EMG sensors have been updated. You can check the firmware version using the Software Update Tool provided by Delsys. For more information, please refer to the user manual.

Delsys Software Setup

Before proceeding with integrating the EMG system into Motive, please make sure the required software for the Delsys Trigno Avanti sensor system is all set up on the host computer. This includes Trigno Control Utility software which will get along with the Trigno EMGworks or Delsys SDK Server package version 3.5.8. For the sensor to work in Motive they must first be configured and paired in the Delsys Trigno Control Utility (TCU) software.

Peripheral Module Setup

In order to integrate Delsys EMG systems with Motive, you will need to setup the required drivers and plugins. Motive installer is packaged with the Peripheral Device module which can be added. During the Motive installation, a list of program features will be shown in the Custom Setup section. Here, change the setting for the Peripheral Device module, as shown in the below image, so that the module is installed along with Motive Files.

Note : Even if you are not using NI-DAQ, it is still necessary to install NI-DAQmx drivers that come up next in the installer.

Device Setup in Motive

Step 1. Launch Delsys Trigno Control Utility software

Make sure to launch the Delsys TCU software first. Make sure all of the sensors have been powered and paired in the TCU software. If the sensors are not detected here, they will not be detected in Motive.

Step 2. Start Motive

Once the sensors are detected and running in the Delsys TCU software, launch Motive. If the peripheral module is installed, Motive will attempt to connect to the Delsys system.

Step 3. Confirm connection

In TCU: If the TCU software is connected to Motive, it will indicate that it has connected to a remote client. As shown in the image below.

Step 4. Enable data channels

Data Channels:

  • Channel 1-16: These are the channels used for reporting raw EMG signals.

  • Channel 17-32: These are the channels used for reporting RMS envelope for the corresponding EMG signal. For example, channel 17 reports RMS envelope of the EMG signals coming through channel 1, and channel 18 reports RMS envelope for channel 2.

Terminal Name

  • The terminal name in Motive correlates to the physical sensor ID given to a Trigno Avanti sensor in Delsys TCU.

Step 5. Enable device

Once you have enabled all of the desired data channels, enable the Trigno device from the Devices pane.

Step 8. Confirm incoming data in Graph pane

As a last step, use the Graph pane to check the EMG data coming through the enabled channels.

Graph Layout:

Synchronization

Setting up triggered sync

  1. If not already, connect the Delsys trigger module into the Trigno base station.

  2. Using a BNC cable, connect one of the output ports on the eSync into the Start Input of the triggered sync box.

  3. [Motive] Set the Type of the connected output port to Recording Gate.

  4. [Motive] Select Trigno device to access its properties.

  5. [Motive] Set the Triggered Sync setting to Device. Note that once Trigno is configured to the Triggered sync mode, EMG data will not be reporting until a recording is started to trigger the Delsys system.

Device Properties: Data Operation

Under Trigno device properties, you can set the following properties to perform data operations to the reported data.

Rectify Values

When enabled, all of the Raw EMG signal coming through channel 1~16 will be rectified and the absolute values of the measurements will be reported.

RMS Envelope Window

RMS is a common way to interpret EMG data. Motive performs RMS envelope calculation when reporting the data just for visualization purposes. For a complete EMG analysis, including additional data filtering for example, the Raw EMG signal should be processed through a separate data analysis software.Size of the RMS envelope can be changed by configuring the RMS Envelope Window property under Trigno device properties. This will set the number of samples used to calculate the RMS reported in Motive. Higher sample size will result in a smoother window and it needs to be adjusted based on the Trigno sampling frequency.

Noise Sample Size

Noise removal can be controlled by the Noise Sample Size property. Set this to 0 to completely disable noise removal.

Data Recording

Once Trigno system is detected in Motive and its channels are enabled, the reported EMG channel data will get recorded along with the motion tracking data. With the triggered sync setup explained above, motion capture system and the EMG system will be synchronized at the start of the recording and they will be running at their own sampling rates after the trigger point. Due to limitation of the triggered synchronization, it is recommended to keep the recordings relatively short.

The Delsys Trigno EMG device samples at a rate of 2000Hz natively, so oftentimes we are down sampling in Motive, and in rare cases, up sampling. We have found that sampling in Motive at a motion capture rate of 100Hz or 200Hz with a multiplier of 10 for the Delsys Trigno EMG device (making its sample rate at 1000Hz or 2000Hz respectively), has shown the best results. When running Motive at 120Hz, however, it has shown to have intermittent frame drops.

For consecutive recordings, please wait at least 5 seconds between each recording to allow the EMG system to get ready for the next recording trigger for proper sync. If not, the data may not get successfully recorded.

Data Playback

Graph Layout with Device Data Plots

  • Right-click on the graph view and set the desired layout dimensions.

  • On one of the graphs, right-click and under the Devices section, select the analog channels you wish to plot.

Data Export

CSV Export: When exporting tracking data into CSV, additional CSV files will be exported separately for each Trigno device in a Take. Each of the exported CSV files will contain basic properties and settings at its header, including device information and sample counts. The voltage amplitude of each analog channel will be listed. Also, mocap frame rate to device sampling ratio is included since analog data is usually sampled at higher sampling rates.

Note that the coordinate system used in Motive (y-up right-handed) may be different from the convention used in the biomechanics analysis software.

Common Conventions

Since Motive uses a different coordinate system than the system used in common biomechanics applications, it is necessary to modify the coordinate axis to a compatible convention in the C3D exporter settings. For biomechanics applications using z-up right-handed convention (e.g. Visual3D), the following changes must be made under the custom axis.

  • X axis in Motive should be configured to positive X

  • Y axis in Motive should be configured to negative Z

  • Z axis in Motive should be configured to positive Y.

This will convert the coordinate axis of the exported data so that the x-axis represents the anteroposterior axis (left/right), the y-axis represents the mediolateral axis (front/back), and the z-axis represents the longitudinal axis (up/down).

Troubleshooting

Q - Delsys Trigno Control Utility software not detecting the base station. Unable to synchronize USB communication.

A - This can happen if the version of the firmwares on the Trigno base station and the sensor is not compatibile with the version of the SDK being used (3.1.2). Please use the Delsys Software Update Tool and make sure the compatible version of the firmware is installed. We recommend using 2905 or 2906 firmware as they are most tested, but any newer versions of the firmware should work also.

Troubleshooting

Delsys EMG box not connecting, error appearing in the Windows Device Manager:
How to wire the DAQ from the breakout wires Delsys EMG base station to DAQ: