LogoLogo
WebsiteSupportDownloadsForumsQuick LinksContact Us
v2.3
v2.3
  • OptiTrack Support Documentation
  • WHAT'S NEW
    • Unreal Engine: OptiTrack InCamera VFX
  • QUICK START GUIDES
    • Quick Start Guide: Getting Started
    • Quick Start Guide: Precision Capture
    • Quick Start Guide: Tutorial Videos
    • Quick Start Guide: Prime Color Setup
    • Quick Start Guide: Active Marker Tracking
    • Quick Start Guide: Outdoor Tracking Setup
  • HARDWARE
    • Cameras
      • Ethernet Cameras
        • PrimeX 41
        • PrimeX 22
        • PrimeX 13
        • PrimeX 13W
        • SlimX 13
        • Prime Color
      • USB Cameras
        • Slim 3U
        • Flex 13
        • Flex 3
        • Duo 3
        • Trio 3
        • Duo 3 and Trio 3 Setup
        • Adjusting Global Origin for Tracking Bars
    • Prepare Setup Area
    • Camera Mount Structures
    • Camera Placement
    • Camera Network Setup
    • Aiming and Focusing
    • Camera Status Indicators
  • MOTIVE
    • Installation and Activation
    • Motive Basics
    • Calibration
      • Continuous Calibration
      • Calibration Squares
    • Markers
    • Assets
      • Gizmo Tool: Translate, Rotate, and Scale
    • Rigid Body Tracking
      • Aligning Rigid Body Pivot Point with a Replicated 3D Model
    • Skeleton Tracking
    • Data Recording
      • Data Types
    • Labeling
    • Data Editing
    • Data Export
      • Data Export: BVH
      • Data Export: C3D
      • Data Export: CSV
      • Data Export: FBX
      • Data Export: TRC
    • Data Streaming
    • Camera Video Types
    • Audio Recording
    • Motive HotKeys
    • Measurement Probe Kit Guide
    • Motive Batch Processor
    • Reconstruction and 2D Mode
    • Tracking Bar Coordinate System
      • Transforming Coordinate System: Global to Local
  • MOTIVE UI PANES
    • Application Settings
      • Settings: Live Reconstruction
      • Settings: General
      • Settings: Views
      • Settings: Assets
        • Skeletons
        • Rigid Body
      • Settings: Camera
    • Mouse and Keyboard
    • Assets Pane
    • Builder Pane
    • Calibration Pane
    • Control Deck
    • Data Pane
    • Data Streaming Pane
    • Devices Pane
    • Edit Tools Pane
    • Graph View Pane
    • Info Pane
    • Labels Pane
    • Log Pane
    • Marker Sets Pane
      • Marker Name XML Files
    • Measurement Pane
    • Probe Pane
    • Properties Pane
      • Properties Pane: Camera
      • Properties Pane: Force Plates
      • Properties Pane: NI-DAQ
      • Properties Pane: OptiHub2
      • Properties Pane: Rigid Body
      • Properties Pane: Skeleton
      • Properties Pane: Take
      • Properties Pane: eSync2
    • Reference View pane
    • Status Panel
    • Toolbar/Command Bar
    • Viewport
  • PLUGINS
    • OptiTrack Unreal Engine Plugin
      • Unreal Engine: OptiTrack Live Link Plugin
      • Unreal Engine: OptiTrack Streaming Client Plugin
      • Unreal Engine: HMD Setup
      • Unreal Engine: MotionBuilder Workflow
      • Unreal Engine VCS Inputs
    • OptiTrack Unity Plugin
      • Unity: HMD Setup
    • OptiTrack OpenVR Driver
    • Autodesk Maya
      • Autodesk Maya: OptiTrack Insight VCS Plugin
    • Autodesk MotionBuilder
      • Autodesk MotionBuilder Plugin
      • Autodesk MotionBuilder: OptiTrack Skeleton Plugin
      • Autodesk MotionBuilder: OptiTrack Optical Plugin
      • Autodesk MotionBuilder: OptiTrack Insight VCS Plugin
      • Autodesk MotionBuilder: Timecode Data
    • OptiTrack Peripheral API
    • External Plugins
      • Houdini 19 Integration
  • ACTIVE COMPONENTS
    • Active Components Hardware
      • Active Puck
      • CinePuck
      • BaseStation
      • Information for Assembling the Active Tags
      • Manus Glove Setup
    • Configuration
      • Active Batch Programmer
      • Active Hardware Configuration: PuTTY
      • Active Component Firmware Compatibility
    • Active Marker Tracking
      • Active Finger Marker Set
      • Active Marker Tracking: IMU Setup
  • SYNCHRONIZATION
    • Synchronization Hardware
      • External Device Sync Guide: eSync 2
      • External Device Sync Guide: OptiHub2
    • Synchronization Setup
    • OptiTrack Timecode
  • VIRTUAL PRODUCTION
    • Unreal Engine: OptiTrack InCamera VFX
    • Entertainment Marker Sets
    • PrimeX 41
  • MOVEMENT SCIENCES
    • Movement Sciences Hardware
      • General Motive Force Plate Setup
      • AMTI Force Plate Setup
      • Bertec Force Plate Setup
      • Kistler Force Plate Setup
      • Delsys EMG Setup
      • NI-DAQ Setup
      • Multiple Device Setup
      • Prime Color Setup
    • Movement Sciences Marker Sets
      • Biomechanics Marker Sets
      • Biomech (57)
      • Rizzoli Marker Sets
    • For Visual3D Users
  • VIRTUAL REALITY
    • VR Plugins
      • VR Unreal Engine
        • OptiTrack Unreal Engine Plugin
        • Unreal Engine: OptiTrack Live Link Plugin
        • Unreal Engine: OptiTrack Streaming Client Plugin
        • Unreal Engine VCS Inputs
      • VR Unity
        • OptiTrack Unity Plugin
      • VR OpenVR
        • OptiTrack OpenVR Driver
    • VR HMD Setup
      • Unreal Engine: HMD Setup
      • Unity: HMD Setup
      • Manually Calibrating the HMD Pivot Point
      • Sync Configuration with an HTC Vive System
    • Navigation Controller Guide
    • SlimX 13
    • Active Marker Tracking
      • Active Finger Marker Set
      • Active Marker Tracking: IMU Setup
    • Synchronization Hardware
      • External Device Sync Guide: eSync 2
      • External Device Sync Guide: OptiHub2
  • ANIMATION
    • Autodesk Maya
      • Autodesk Maya: OptiTrack Insight VCS Plugin
    • Autodesk MotionBuilder
      • Autodesk MotionBuilder Plugin
      • Autodesk MotionBuilder: OptiTrack Skeleton Plugin
      • Autodesk MotionBuilder: OptiTrack Optical Plugin
      • Autodesk MotionBuilder: OptiTrack Insight VCS Plugin
      • Autodesk MotionBuilder: Timecode Data
  • ROBOTICS
    • PrimeX 22
    • Outdoor Tracking Setup
  • DEVELOPER TOOLS
    • Developer Tools Overview
    • NatNet SDK
      • NatNet 4.0
      • NatNet: Class/Function Reference
      • NatNet: Creating a Managed (C sharp) Client Application
      • NatNet: Creating a Native (C++) Client Application
      • NatNet: Data Types
      • NatNet: Matlab Wrapper
      • NatNet: Migration to NatNet 3.0 libraries
      • NatNet: RebroadcastMotiveData Sample
      • NatNet: Remote Requests/Commands
      • NatNet: Sample Projects
      • NatNet: Unicast Data Subscription Commands
      • Latency Measurements
    • Motive API
      • Motive API: Quick Start Guide
      • Motive API Overview
      • Motive API: Function Reference
      • Motive API Camera Calibration
    • Camera SDK
      • Camera SDK Classes
        • Class: cCameraGroupFilterSettings
        • Class: cCameraGroupMarkerSizeSettings
        • Class: cCameraGroupPointCloudSettings
        • Class: cCameraModule
        • Class: cRigidBodySettings
        • Class: cRigidBodySolutionTest
        • Class: cTTAPIListener
        • Class: cUID
  • MARKER SETS
    • Full Body
      • Baseline (37)
      • Baseline + Hinged Toe (41)
      • Baseline + Hinged Toe, with Headband (41)
      • Baseline + 13 Additional Markers (50)
      • Biomech (57)
      • Conventional (39)
    • Full Body + Fingers
      • Baseline + Hinged Toe + Fingers (49)
      • Baseline + 11 Additional Markers + Fingers (54)
      • Manus Glove Setup
    • Upper
      • Baseline Upper (25)
      • Baseline Upper Body + Fingers (33)
      • Conventional Upper (27)
    • Lower
      • Baseline Lower (20)
      • Helen Hayes Lower (19)
      • Conventional Lower (16)
    • Hand and Fingers
      • Left and Right Hand (11)
      • Active Finger Marker Set
    • Rizzoli Marker Sets
    • Entertainment Marker Sets
    • Rigid Body Skeleton Marker Set
  • GENERAL TROUBLESHOOTING
    • Troubleshooting
    • Running Motive on High DPI Displays
    • Firewall Settings
Powered by GitBook
On this page
  • General
  • Calibration Info
  • Camera Filters - Software
  • Solver/Reconstruction Settings

Was this helpful?

Export as PDF
  1. MOTIVE UI PANES
  2. Properties Pane

Properties Pane: Take

PreviousProperties Pane: SkeletonNextProperties Pane: eSync2

Last updated 2 years ago

Was this helpful?

When a is selected from the , related information will be displayed in the .

From the Properties pane, you can get the general information about the Take, including the total number of recorded frames, capture data/time, and the list of assets involved in the recording. Also, when needed, the solver settings that were used in the recorded TAK can be modified, and these changes will be applied when performing post-processing reconstruction.

General

Name

Take name

Frame Rate

The camera frame rate in which the take was captured. The Take file will contain the corresponding number of frames for each second.

Start Frame

The frame ID of the first frame saved on the Take.

End Frame

The frame ID of the last frame saved on the Take.

Start Time

A timestamp of when the recording was first captured started.

End Time

A timestamp of when the recording was ended.

Assets

Names of assets that are included in the Take

Notes

Comments regarding the take can be noted here for additional information.

Best

Capture Data/Time

Date and time when the capture was recorded.

Captured in Version

The version of Motive which the Take was recorded in. (This applies only to Takes that were captured in versions 1.10 or above)

Captured in Build

The build of Motive which the Take was recorded in.

Health State

The data quality of the Take which can be flagged by users.

Progress

Progress indicator for showing how into the post-processing workflow that this Take has made.

Calibration Info

Camera system calibration details for the selected Take. Takes recorded in older versions of Motive may not contain this data.

Calibration Time Stamp

Shows when the cameras were calibrated.

Residual Mean Error

Residual 50/95/99 Percentile Error

Wand Mean Error

Displays a mean error value of the detected wand length samples throughout the wanding process.

Wand 50/95/99

Displays percentile distribution of the wand errors.

Calibration Wand

Shows what type of wand was used: Standard, Active, or Micron series.

Wand Length

Displays the length of the calibration wand used for the capture.

Wand Center Offset

Distance from one of the end markers to the center marker, specifically the shorter segment.

Camera Filters - Software

Solver/Reconstruction Settings

Marks the best take. Takes that are marked as best can also be accessed via scripts.

Shows mean offset value during calibration.

Displays percentile distribution of the errors.

The camera filter settings in the Take properties determine which IR lights from the recorded 2D camera data contributes to the when re-calulating the 3D data when needed.

For more information on these settings in Live mode, please refer to the page.

The Solver/Reconstruction settings under the Take properties are the 3D data solver parameters that were used to obtain the saved in the Take file. In Edit mode, you can change these parameters and perform the to obtain a new set of 3D data with the modified parameters.

For more information on these settings in Live mode, please refer to the page.

Motive Batch Processor
residual
residual
Application Settings: Live Pipeline
Application Settings: Live Pipeline
Data pane
Properties pane
3D data
post-processing reconstruction pipeline
post-processing reconstruction pipeline
Take
Take properties listed under the .
Properties pane